| OPERATIONAL |
 |
 |
 |
 |
|
Light Source
|
|
Visible Laser Diode 675 nm ± 5 nm
|
 |
 |
 |
 |
|
Laser Power
|
|
0.800 mW (peak)
|
 |
 |
 |
 |
|
Depth of Scan Field
|
|
12.7" mm - 203 mm (0.5” - 8”) for 0.33 mm (13 mil) bar code
|
 |
 |
 |
 |
|
Width of Scan Field
|
|
28.6 mm (1.125”) @ face; min 102 mm (4”) @ 76.2 mm (3”)
|
 |
 |
 |
 |
|
Scan Speed
|
|
52 scan lines per second
|
 |
 |
 |
 |
|
Scan Pattern
|
|
Single scan line
|
 |
 |
 |
 |
|
Minimum Bar Width
|
|
0.173 mm (6.8 mil)
|
 |
 |
 |
 |
|
Decode Capability
|
|
Autodiscriminates all standard bar codes; for other symbologies call Metrologic
|
 |
 |
 |
 |
|
System Interfaces
|
|
RS232, Light Pen, PC Keyboard Wedge, Stand Alone Keyboard
|
 |
 |
 |
 |
|
Print Contrast
|
|
35% minimum reflectance difference
|
 |
 |
 |
 |
|
Roll, Pitch, Yaw
|
|
42°, 68 °, 52°
|
 |
 |
 |
 |
|
Beeper Operation
|
|
3 tones or no beep
|
 |
|
 |
 |
 |
|
Number Characters Read
|
|
Up to 80 data characters
|
 |
 |
 |
 |
|
Indicators(LED
|
|
Red = Laser on, ready to scan; Green = Good read
|
 |
|
 |
| MECHANICAL |
 |
 |
 |
 |
|
Termination
|
|
Breakaway connector or 10 position modular RJ45
|
 |
 |
 |
 |
|
Cable
|
|
Straight breakaway or 1.5 m (5') coiled
|
 |
|
 |
| ELECTRICAL |
 |
 |
 |
 |
|
Input Voltage
|
|
5 VDC ± 0.25 V
|
 |
 |
 |
 |
|
Power
|
|
IS4210: 0.43 W IS4220: 0.75 W
|
 |
 |
 |
 |
|
Operating Current
|
|
IS4210: 85 mA IS4220: 135 mA
|
 |
 |
 |
 |
|
DC Transformers
|
|
Class 2; 5 VDC @ 300 mA
|
 |
 |
 |
 |
|
Laser Class
|
|
CDRH: Class IIa; EN60825-1:1994/A11:1996 Class 1
|
 |
 |
 |
 |
|
E M C
|
|
FCC Class A, CISPR Class A
|
 |
|
 |
| ENVIRONMENTAL |
 |
 |
 |
 |
|
Operating Temperature
|
|
-20°C to 50°C (-4°F to 122°F)
|
 |
 |
 |
 |
|
Storage Temperature
|
|
-40°C to 70°C (-40°F to 158°F)
|
 |
 |
 |
 |
|
Humidity
|
|
5% to 95% relative humidity, non-condensing
|
 |
 |
 |
 |
|
Light Levels
|
|
Up to 4842 Lux (450 footcandles)
|
 |
 |
 |
 |
|
Shock
|
|
Designed to withstand 1.5 m (5') drops
|
 |
 |
 |
 |
|
Contaminants
|
|
Sealed to resist airborne particulate contaminants
|
 |
 |
 |
 |
|
Ventilation
|
|
None required
|
 |
|
 |
| ACCESSORIES |
 |
 |
 |
 |
|
Article / Order No.
|
|
MK = Metrologic Kit
|
 |
 |
 |
 |
|
MK 4220-41 RS 232 KIT
|
|
Kit includes Communication and Connection Cable, Power Supply, Glove and MCA converter
|
 |
 |
 |
 |
|
MK 4220-17 KBW Kit
|
|
Kit includes Communication and Connection Cable, Power Supply, Glove and MCA converter
|
 |
 |
 |
 |
|
45-45455
|
|
Glove ( Included in Kit)
|
 |
 |
 |
 |
|
MCA 951
|
|
RS 232 Converter ( Included in Kit)
|
 |
|
 |
 |
 |
|
46-46009
|
|
Power Supply (included in Kit if needed)
|
 |
|
 |
 |
 |
© Metrologic Instruments GmbH, all rights reserved |
 |
Top |
 |
|
Terms |
Impressum |
|
|