| SCAN PERFORMANCE |
 |
 |
 |
 |
Depth of Field (programmable
|
|
0 mm - 254 mm (0” - 10”) for 0.33 mm (13 mil) bar codes
|
 |
 |
 |
 |
|
Field of View
|
|
49 mm W x 19 mm H (1.9” W x 0.8” H) @ 20 mm (0.8”); 264 mm W x 106 mm H (10.4” W x 4.2” H) @ 280 mm (11”)
|
 |
 |
 |
 |
|
Minimum element width, 1D
|
|
0.127 mm (5 mil)
|
 |
 |
 |
 |
|
Minimum element width, 2D
|
|
0.254 mm (10 mil)
|
 |
 |
 |
 |
|
Print Contrast
|
|
20% minimum reflectance difference
|
 |
|
 |
| OPERATIONAL |
 |
 |
 |
 |
|
Light Source
|
|
LED 645 nm +7.5 nm
|
 |
 |
 |
 |
|
Decode Capability
|
|
Autodiscriminates all standard 1-D, RSS, PDF417, microPDF, MaxiCode, Data Matrix, QR Code, UCC, EAN Composites, Postals, Aztec
|
 |
 |
 |
 |
|
System Interfaces
|
|
Bluetooth v1.2
|
 |
 |
 |
 |
|
Beeper Operation
|
|
7 tones or no beep
|
 |
 |
 |
 |
|
Indicators (LED)
|
|
Blue Steady=unit powered, ready to scan, Bluetooth connected; White=good read; Yellow Steady=in stand
|
 |
 |
 |
 |
|
Battery Indicator (LED)
|
|
Blue=unit powered
|
 |
|
 |
| MECHANICAL |
 |
 |
 |
 |
|
Width
|
|
Handle - 30 mm (1.2”); Head - 79 mm (3.1”)
|
 |
|
 |
| ELECTRICAL |
 |
 |
 |
 |
|
Battery Capacity
|
|
9,000 scans (average)
|
 |
 |
 |
 |
|
Radio Range
|
|
Bluetooth Class 2 - 10 m (33’)
|
 |
 |
 |
 |
|
Frequency
|
|
2.4 - 2.48 GHz (frequency hoping)
|
 |
 |
 |
 |
|
DC Transformers
|
|
Scanner: none; Base: Class 2; 5VDC < 1A
|
 |
 |
 |
 |
|
EMC
|
|
FCC Class A, IEC60825-1 LED Safety
|
 |
 |
 |
 |
|
ESD Protection
|
|
Functional after 100 15kV discharges
|
 |
 |
 |
 |
|
LED Class
|
|
Class 1; IEC60825-1:1993/A1:1997+A2:2001 Class 1; EN60825-1:1994/A11:1996+A2:2001
|
 |
|
 |
| ENVIROMENTAL |
 |
 |
 |
 |
|
Operating Temperature
|
|
0°C to 40°C (32°F to 104°F)
|
 |
 |
 |
 |
|
Storage Temperature
|
|
-20°C to 50°C (-4°F to 120°F)
|
 |
 |
 |
 |
|
Humidity
|
|
0% to 95% relative humidity, non-condensing
|
 |
 |
 |
 |
|
Light Levels
|
|
Up to 190,000 Lux (17,670 footcandles)
|
 |
 |
 |
 |
|
Shock
|
|
Designed to withstand 1.5 m (5’) drops
|
 |
 |
 |
 |
|
Contaminants
|
|
Sealed to resist airborne particulate contaminants
|
 |
|